Summarize this post with AI
Choose a magnetic door contact by checking its active gap against the planned door-and-contact arrangement and confirming that its installation method suits the opening. This guide explains what installers should verify, how to avoid common selection errors, and how to plan contacts as part of a wider intrusion detection system.
Table of Contents
- Key Takeaways
- What to Look for in a Magnetic Door Contact
- How the 15–25 mm Active Gap Affects Contact Selection
- Planning a Complete Intrusion Detection System
- Common Magnetic Door Contact Selection Mistakes
- Frequently Asked Questions
- How many magnetic door contacts does an intrusion alarm system need?
- Can one magnetic door contact monitor more than one door?
- How can installers check that a door contact is operating after installation?
- Can a magnetic door contact be used with a wireless alarm system?
- Glossary
Key Takeaways
- Check the contact’s stated active gap against the actual mounting arrangement before specifying it.
- Confirm that the installation method is practical for the door and frame where the contact will be fitted.
- Include every opening to be monitored in the system plan, then confirm how the alarm system will supervise those points.
- Test the installed contact using the alarm system’s procedures rather than relying on appearance alone.
What to Look for in a Magnetic Door Contact
Start with two installation checks: the required active gap and the method used to fit the contact. Both affect whether a particular model is appropriate for the opening and mounting arrangement.
The Flair Conceal Mount Magnetic Door Contact uses press-fit installation and has a stated active gap of 15–25 mm. Compare those details with the site conditions and the product documentation before specifying it.
Also consider the broader installation plan: the openings to monitor, the alarm system’s input arrangement, and how the installer will verify operation once fitting is complete.
How the 15–25 mm Active Gap Affects Contact Selection
An active gap is the specified separation range between the contact and its magnet for the intended arrangement. Check this requirement against the actual door, frame, and proposed mounting positions; do not assume a stated range will suit every opening.
For a contact specified with a 15–25 mm active gap, confirm the separation at the planned closed-door position and follow the product documentation for alignment and installation. If the physical arrangement does not match the stated range, reassess the mounting plan or select a contact whose documented requirements fit the site.
Where doors, frames, or mounting positions vary across a project, check each opening rather than treating one measurement as representative of the whole site.
Planning a Complete Intrusion Detection System
A door contact is one part of an intrusion detection plan. First identify which doors need monitoring, then coordinate those points with the alarm system layout and the installer’s method for testing each opening.
For a broader view of available system components, explore the intrusion detection products collection as you plan the installation.
Keep a point schedule that records each opening, its intended monitoring point, and the relevant product requirements. This makes it easier to review coverage and verify that the selected contact’s active gap and installation method have been considered for each location.
Common Magnetic Door Contact Selection Mistakes
- Ignoring the active gap: Check the specified range against the planned contact-and-magnet arrangement for each opening.
- Overlooking the installation method: Confirm that press-fit installation is suitable for the intended fitting location and installation plan.
- Assuming every opening is alike: Review door and frame conditions separately where they differ across the site.
- Skipping the operating check: After installation, follow the alarm system’s test procedure and confirm the opening is represented as intended.
These checks help catch specification mismatches before the installation is treated as complete.
Frequently Asked Questions
How many magnetic door contacts does an intrusion alarm system need?
There is no fixed number; count the doors that the project requires the alarm system to monitor. The system design determines how those monitoring points are arranged and supervised. List each opening during planning, then confirm the alarm panel’s input arrangement and any project requirements with the system documentation or responsible integrator.
Can one magnetic door contact monitor more than one door?
A single contact is associated with its own installation position, so do not assume it can independently monitor several separate doors. A system designer may consider how multiple monitoring points are arranged, but the alarm system and project requirements determine the appropriate configuration. Plan and verify each opening rather than treating one contact as coverage for multiple doors.
How can installers check that a door contact is operating after installation?
Use the alarm system’s documented test procedure and check the monitoring point while moving the door between its open and closed positions. Confirm that the system reports the expected change for that opening. If the response is unclear, review the contact’s placement, alignment, and specified active gap, then follow the relevant installation guidance.
Can a magnetic door contact be used with a wireless alarm system?
Compatibility depends on the contact and the wireless alarm system; the information given here does not establish wireless compatibility for this contact. Before specifying a device, check its documentation and the alarm system’s requirements, including how the monitoring point connects to the system. Ask the system supplier or integrator to confirm compatibility if the documentation is unclear.
Glossary
- Active gap: The specified separation range between a contact and its magnet for the intended arrangement.
- Press-fit installation: An installation method in which a component is fitted by pressing it into its intended mounting position.
- Monitoring point: An opening or location that the intrusion detection system is set up to monitor.
The Flair Conceal Mount Magnetic Door Contact is worth considering when its press-fit installation method and stated active gap align with the site’s requirements. Review its product information alongside the system plan before finalising your specification.

Flair Conceal Mount Magnetic Door Contact
Flair conceal mount magnetic door contact-Press fit installation-Active gap from 15mm to 25mmMOQ = 20 Pcs/Pack Data Sheet Data Sheet - Tegas Integrasi is available online now at tegas-integrasi.com. Sign up as our dealer and make your order
Reliable selection starts with matching the contact’s documented requirements to each opening, then testing the completed installation. Explore the available intrusion detection options to support your project planning.